Features
Differential Measurement Function
Lets you select one channel as the reference and read the difference between the measured
and
reference channels on the datalogger's LCD display.
Logging Mode
The logging function lets you use the OM-2000 Series datalogger with up to six input
channels. Up to 23 logging function groups can be set up, with free selection of
measurement interval, logging period and individual channel ranges. Logging period can be
as long as one month. Internal memory stores up to 13,951 readings. With a 64K bytes
memory card, up to 30,302 readings can be stored.
Memory Read Mode
Reads stored data back from the memory to the display. Lets you pause temporarily during
readback and step through data. Also lets you identify a measurement time by displaying
time of day or elapsed time after logging start.
Memory Card Operation
Data saved on the memory card can be played back on an OMEGA¿ RD3720 or RD3750
Series recorder equipped with a memory card interface. The RD3720 can be used with any
of the memory cards available. The RD3750 requires the 64K memory card.
Analog Output Function
A single channel's readings can
be output to a recorder or other instrument as an analog output signal of 0.1 mV/digit. In
manual measurement and memory read modes, outputs data for any selected channel. In
logging mode, outputs data for Channel 1.
Data Transmission via RS-232C
The RS-232C port lets you transmit stored data from memory or real-time measurements
(real time transmission only with OM-2020 isolated model) when in the logging mode.
Applications Software
The OMEGA¿ OM-2000 Series portable datalogger system includes software that
enables you to acquire and review your data in ASCII columnar format and transfer it to
other software products such as Lotus 123. The software is designed to operate on IBM
PC/XT/AT or compatible computers running MS-DOS 2.1 or higher.
COPY [To Your Hard Drive] OM-2000 DOS Software Now! (requires OM-2000 datalogger)